• 78

FAF Products

Bottom Replacement Terminal HEPA Filter Module

Short Description:

● Lightweight, compact ducted filter module for clean processes or medical suites.


Product Detail

Product Tags

Features:
•  It has high efficiency, low resistance, and light weight, which makes it easy to install and operate.
•  It can adjust the air volume according to the needs of the clean room, and it has a negative pressure sealing mechanism to prevent air leakage. It can be connected with round hose or spiral air duct for flexible installation.
•  It has a dry sealed ceiling design that is suitable for clean rooms with high standards of cleanliness and hygiene.
•  Its biggest feature is that it allows the high-efficiency filter to be replaced directly under the air outlet without affecting the cleanliness of the workshop. This saves time and cost, and ensures the quality of the clean room environment.

Bottom replacement HEPA filter module

Composition materials and operating conditions:
•  The frame is made of aluminum alloy, and the top cover is made of galvanized sheet for durability and corrosion resistance.
•  The air duct interface has a diameter of 250mm, 300mm, or 350mm, and a height of 80mm, 100mm, or 120mm, depending on the customer’s preference.
•  The high-efficiency filters are H13 or H14 grade, and they are partition-free for better airflow. The thickness of the high-efficiency filter is 70mm.
•  The high-efficiency filter is fixed by a special pressing block made of aluminum alloy profiles, which ensures a tight seal and easy replacement.
•  The diffusion plate can be either painted or flow equalizing film, depending on the customer’s needs. The diffusion plate helps to distribute the air evenly in the clean room.
•  The air volume can be increased by expanding the filtration area, which is achieved by increasing the number of folds in the filter. This allows more air to pass through the filter without compromising the efficiency.
•  To extend the life of the high-efficiency filter, it is recommended to operate it at low wind speed. This will reduce the wear and tear on the filter and maintain its performance.
•  The maximum operating temperature and humidity for the clean room air outlet are 80°C and 80%, respectively. These conditions should not be exceeded to avoid damaging the components.

Clean Room HEPA Ceiling Modules

Common product specifications, models, and technical parameters

Model Size(mm) Air Flow(m³/h) Initial Pressure
(Pa)
Efficiency
MPPS
Structure Type
SAF-YTH-X10 Box 1170x570x150 1000 ≤115±20% H13(99.97%)@0.3μmH14(99.995%)@0.3μm Bottomreplacement
Hepa 1138*538*70
SAF-YTH-X12 Box 1220x610x150 1200
Hepa 1188*578*70
SAF-YTH-X10A Box 1170x570x180 1000 ≤115±20% H13(99.97%)@0.3μmH14(99.995%)@0.3μm Bottomreplacement
Hepa 1138*538*70
SAF-YTH-X12A Box 1220x610x180 1200
Hepa 1188*578*70

Note: This product can accept non-standard customization.