1. There are two type of air circulation: horizontal open loop and vertical close loop.
Open loop air circulation is as follows, the main feature is that in each cycle all the air is collected from the outside through clean bench box and returned to the atmosphere directly. The general horizontal flow super-clean working table adopts the opening loop, this kind of clean bench structure is simple, cost is low, but the fan and filter load are heavily, it has a bad effect on using life, at the same time the cleaning efficiency of fully open air circulation is not high, usually only for low cleanliness requirements or biological hazards environment.
The closed loop is not actually a complete inner air flow cycle. Air will be discharged into the atmosphere in each cycle, after passing through the working area, 70% of the gas passes through the orifice and enters the nest cycle again. Compared to the outside air, the gas is still relatively pure, so the filter load is lighter, services life will also be longer, and this air circulation is adopted by the current main clean bench product.
2. The vertical ultra clean bench installs ultraviolet lamp for disinfection and sterilization.
The 1.5 thick high-quality cold rolled steel plate by electrostatic spraying treatment (or stainless steel)
Stainless steel work table
High quality centrifugal fan
American Dwyer differential pressure gauge.
With Pre-HEPA two stage filtration, easy to operate, equipped with universal wheel, can move in every direction.
A variety of models can be customized to meet the specific needs of customers.
Operation procedures:
(1) Turn the machine 50 minutes in advance when using the work bench, turn on the lamp at the same time, treatment of microorganisms accumulated on the surface of operation area, turn off the germicidal lamp after 30 minutes (when the fluorescent lamp is on), start the fan.
(2) for newly installed or long-term unused work stations, it is necessary to clean the table and surrounding environment with a super-static vacuum cleaner of with tools that do not produce fiber before using, the UV method was used for further treatment.
How to select a clean bench:
You must pay attention to super clean bench fan (blower )and filter! these two things show the level of product technology, can't be faked, we use EBM fan.
Laboratory biological photoelectric industry microelectronic/ hard disk manufacturing and other fields.
Model | SAF-VC-1000 | SAF-VC-1200 | SAF-VC-1500 | SAF-VC-1800 |
External Size (mm) | W1000*D700*H1800 | W1200*D700*H1800 | W1500*D700*H1800 | W1800*D700*H1800 |
Internal Size (mm) | W900*D650*H600 | W1100*D650*H600 | W1400*D650*H600 | W1700*D650*H600 |
Table Height(mm) | 750 | 750 | 750 | 750 |
Clean Class Level | 100Class 0.3µm(ISO14644-1 International Standard) | |||
Rated Air Flow | 900m3/h | 1200m3/h | 1500m3/h | 1800m3/h |
Air Velocity | 0.3-0.6m/s | 0.3-0.6m/s | 0.3-0.6m/s | 0.3-0.6m/s |
HEPA Efficiency | 99.99% 0.3µm above (H13-H14) | |||
Vibration Half Peak | damping separate countertops (optional) | |||
Noise | ≤50dB | ≤50dB | ≤50dB | ≤50dB |
Material | Cabinet: epoxy powder coated steel or stainless steel, Table-board: stainless steel | |||
Illumination | ≥300lux | ≥300lux | ≥300lux | ≥300lux |
LED light | 9W*1 | 13W*1 | 18W*1 | 24W*1 |
Power | 124W | 127W | 200W | 248W |
Noise | ≤50dB | ≤50dB | ≤50dB | ≤50dB |
Power Supply | 220V/50Hz | 220V/50Hz | 220V/50Hz | 220V/50Hz |
Suitable Person | 1 | 1-2 | 2-3 | 3-4 |